Armtec Provides Alternative Solution to Storm Sewer Tender

Project Location Owner:Town of Springdale

Project Location Engineer:SNC Lavalin

Project Location Contractor:Budgell's Equipment

Project Location Location:Springdale, NL

Armtec - Armtec Provides Alternative Solution to Storm Sewer Tender
In late November, as the construction season was winding down, a large tender was called for the small municipality of Springdale in Central Newfoundland. The town's storm sewer system required the addition of 590m of 1,050m diameter pipe. The original specification called for High Density Polyethylene (HDPE) pipe. With limited supplies and a tight construction window, an alternative product was required.

Product Utilized: UltraFlo Corrugated Steel Pipe

The Challenge

The original project included 590m of 1,050mm diameter HDPE pipe to be used as a main storm sewer line through the Town of Springdale. Armtec however did not have adequate stock of 1,050mm diameter HPDE pipe at the nearby Bishop’s Falls facility. Given the large quantity and the time of year, 13 truckloads of pipe would have needed to be shipped in from another location, significantly adding to the overall project cost.

The Solution

Realizing that providing the HDPE solution was not an option for Armtec, the consultant on this project was called to see if UltraFlo Storm Sewer Pipe could be used as an alternate. After providing additional information and specifications, an addendum was issued that UltraFlo would be accepted as an alternative to the 1,050mm diameter HDPE. Another important factor in this decision was that the UltraFlo Storm Pipe would be manufactured in Newfoundland rather than the HDPE pipe which would need to be manufactured outside of the province, regardless of who provided the HDPE. Shortly after the addendum was issued, Armtec prepared the quotation and submitted it to the contractor bidding the project. Budgell’s Equipment, located in the Town of Springdale was the successful bidder. Armtec then immediately entered into negotiations for the project. The following day, the order for the UltraFlo was placed. Working with the consultant to better understand the options available in storm sewer applications and the benefits of UltraFlo, along with the ability to quickly manufacture the product allowed Armtec to secure this project and ship the materials to the job-site on time and within budget.

Technical Details

1,050m diameter, 590m long