× Notice: This website or its third-party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy. By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.
×
Serving our customers through changing times.

Discover our new online meeting tool

Schedule a one on one virtual planning session with a professional civil engineer.

Connect With an Engineer

Stormwater Solution For YVR Employee Parking Lot

Owner: YVR - Vancouver International Airport
Contractor: Urban Systems Ltd., Hexcel Construction Ltd.
Location: Richmond, BC

Armtec is proud to have been chosen as the supplier of 1,400mm diameter Polymer Coated CSP Detention Tank, CSP Manholes, and Pro-Eco-Lite headwall for the construction of the North Service Road employee parking lot at YVR.

YVR services more than 17 million passengers each year and is ranked one of the top airports in the world. Looking to move beyond their current airport operations, YVR has announced plans to build a 460,000 ft2 designer brand retail outlet with over 200 shops.

In order to accommodate this new retail space, the Vancouver Airport Authority needed to relocate the employee parking lot to North Service Road and Aviation Avenue. Urban Systems Limited was chosen by the Vancouver Airport Authority to design the new parking lot.

Their designs called for a 200m3 storm water detention tank to maintain natural predevelopment groundwater flow. One of the design specifications was that the system would need to fit into a trench width of 4.5m and a maximum depth of 1.9m to accommodate a high water table.

It was also YVR’s mandate that the storm system meet a minimum 75-year design service life. With these specifications in mind, Armtec and Urban Systems Ltd. worked together to select a CSP system that would realize the design plans:

Step One:

Selected a pipe size that would allow the system to fit within the vertical constraints while maintaining a minimum cover of 300mm for a CL-625 highway vehicle live load

Step Two:

Determined a length of pipe that could meet the stormwater detention storage requirements

Step Three:

Fit the system into the available 60m x 4.8m footprint. Using the Corrugated Steel Pipe Institute “Canadian Durability Guideline for CSP Culverts”, it was determined that polymer coated CSP would provide a service life in excess of the desired 75 years. The team also chose to use Armtec H-500 Huggerband couplers because of their ability to limit infiltration as well as their high pull apart resistance, which also helped ensure their 75-year service life mandate. Urban Systems and YVR compared the Polymer CSP detention tank to a precast concrete box culvert solution. Ultimately, USL selected the CSP option based on a combination of economics, speed of installation, and its ability to fit within the site area constraints.

The detention tank was one of the first underground components required at the jobsite to ensure that the project was completed on schedule. The Vancouver Airport Authority purchased the tank on the condition that the structure would be delivered within four weeks. From start to finish, including preparation of certified engineered drawings, delivery was completed in three weeks six days. Installation was completed in 10 working days.

  • 1,400mm diameter polymer coated CSP detention tank
  • CSP manholes
  • Pro-Eco-Lite headwall